Section 3 Front Panel Operation
3.38
Match? XXXXXXXXXXXXX
(bin)
Requests the bus pattern for match. Bus data and signal line patterns
are specified as true (
1
), false (
0
) or don't care (
X
). When displaying
hexadecimal data, changing the hexadecimal data byte automatically
changes the corresponding bus message. Use the [
] and [
]
cursor keys to move between input fields. Use the [
] and [
] cursor
keys to set values. Pressing
[
]
at the
NUL
bus message selects a
bus error (
ERROR
). Accept entry with
[ENTER]
and
[EXIT]
or
cancel with
[ESC]
.
# of Matches? 00001
Requests the number of times the bus pattern should match before
starting the trigger delay.
Number of matches
can be from 1 to
65,535. Accept entry with
[ENTER]
and
[EXIT]
or cancel with
[ESC]
.
Trig Delay? 0000000
Requests the number of events to delay before starting the post
count.
Trig delay
can be from 1 to 9,999,999. Accept entry with
[ENTER]
and
[EXIT]
or cancel with
[ESC]
.
Post Count? 00000
Requests the number of events in the trigger post count.
Post
count
can be from 1 to 32,767. Accept entry with
[ENTER]
and
[EXIT]
or cancel with
[ESC]
.
When Complete? Stop
Requests the recording action to be taken following the completion
of the post trigger count. The two choices are:
Stop
or
Step
.
Stop
allows the activity on the bus to continue at the selected handshake
speed.
Step
continues recording at single-step handshake rate (use