Example 3: WaveBook/516A System with a WBK25, WBK17, and a WBK10A
Device Interface Side Channel Input Side
WaveBook/516A System
with a WBK25, WBK17, and a WBK10A
WBK10A
WBK17
WaveBook/516A
WBK25
Power
Power
Ethernet
Lines and Cables Used in Example 3, excluding channel input connections.
1. Power Supply - To the WaveBook/516A POWER IN DIN 5 connector, +10 VDC to +30 VDC,
typically from a TR-40U power adapter.
2. Power Supply – From the WaveBook/516A’s POWER OUT DIN 5 connector to the WBK25’s
POWER IN DIN 5 connector via a CA-115 Power Cable.
3. Power Supply - To the WBK17’s POWER IN DIN 5 connector, +10 VDC to +30 VDC, typically
from a TR-40U power adapter.
4. Power Supply – From the WBK17’s POWER OUT DIN 5 connector, +10 VDC to +30 VDC, to the
WBK10A’s POWER IN DIN 5 connector via a CA-115 Power Cable.
5. Ethernet – From the WBK25’s ETHERNET jack to a 10/100BaseT Ethernet Network or to the
ETHERNET jack on a PC. Applicable Ethernet patch cables (1.5-foot or 7-foot) are CA-242 and
CA-242-7, respectively.
6. Expansion – From the WBK25’s EXPANSION PORT 1 to the WaveBook/516A’s PARALLEL
PORT connector. The connection is made via a 25-pin CA-35-12 cable.
7. Expansion Control – From WaveBook/516A’s EXPANSION CONTROL to the WBK17’s
EXPANSION CONTROL IN. Connection is via a 15-pin CA-129 cable.
8. Expansion Control – From the WBK17’s EXPANSION CONTROL OUT to the WBK10A’s
EXPANSION CONTROL IN. Connection is via a 15-pin CA-129 cable.
9. Expansion Signal – From the WBK10A’s EXPANSION SIGNAL OUT to the WBK17’s
EXPANSION SIGNAL IN. Connection is via a BNC coaxial CA-150 cable.
10. Expansion Signal – From the WBK17’s EXPANSION SIGNAL OUT to the WaveBook/516A’s
EXPANSION SIGNAL IN. Connection is via a BNC coaxial CA-150 cable.
11. Digital Expansion – This connection is made on the channel input side of the units. The cable runs
from the WaveBook/516A’s DIGITAL I/O / EXTERNAL CLOCK / TTL TRIGGER connector to
the WBK17’s IN-DIGITAL EXPANSION connector (HD26 type). The connection is made via a
CA-217 Digital Expansion Cable.