Section 3 Command Descriptions
3.9
Data received for output to the digital ports must be contained within a
prefix (
D
) and a suffix (
Z
). If the amount of data sent is less than the number of
bits programmed as outputs, the least-significant bits will contain the data sent
and the most-significant bits will be cleared to logic zero. If the data sent is
greater than the number of bits programmed for output or selected by the
Pn
command, the
Digital232
will generate a conflict error and ignore the entire
command string. The
Data Strobe
output is pulse for approximately 50
microseconds after new data is output on the selected port(s).
Example:
F1
select ASCII mode
R0
read data from the
Digital232
,
display shows 4>6;
D1??2Z
send 1??2 to the
Digital232
R0
read data from the
Digital232
,
display shows 1??2
F2 Format - ASCII Binary
In the
F2
format, the each data bit is described with an ASCII 0 or 1. Each
byte is formatted in two 4-bit multiples separated by semicolons.
F2 String Decimal
Equiv F2 String Decimal Equiv
0000;0000 0 0000;1001 9
0000;0001 1 0000;1010 10
0000;0010 2 0000;1011 11
0000;0011 3 0000;1100 12
0000;0100 4 0000;1101 13
0000;0101 5 0000;1110 14
0000;0110 6 0000;1111 15
0000;0111 7 1000;0001 129
0000;1000 8 1111;1111 255