Measurement-computing CIO-CTRxxHD Uživatelský manuál Strana 6

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 20
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 5
3.1 BASE ADDRESS
Unless there is already a board
in your system which uses
address 300h (768 Decimal)
then you can leave the
switches as they are set at the
factory.
In the example shown here,
the CIO-CTR##HD is set for
base address 300h (768
Decimal).
Certain address are used by the PC, others are free and can be used by the
CIO-CTR##HD and other expansion boards. We recommend trying BASE = 300h
(768D) first.
SERIAL PORT3F8-3FFEGA2B0-2BF
FLOPPY DISK3F0-3F7PARALLEL PRINTER270-27F
SERIAL PORT3E8-3EFALT BUS MOUSE23C-23F
EGA3C0-3CFEXPANSION UNIT (XT)210-21F
PARALLEL PRINTER3BC-3BFGAME CONTROL200-20F
MDA3B0-3BBHARD DISK (AT)1F0-1FF
SDLC3A0-3AF80287 NUMERIC CO-P
(AT)
0F0-0FF
SDLC380-38F8237 #2 (AT)0C0-0DF
PARALLEL PRINTER378-37FNMI MASK (XT)0A0-0A1
HARD DISK (XT)320-31F8259 PIC #2 (AT)0A0-0AF
PROTOTYPE CARD310-31FDMA PAGE REGISTERS080-08F
PROTOTYPE CARD300-30FCMOS RAM & NMI
MASK (AT)
070-071
SERIAL PORT2F8-2FF8742 CONTROLLER (AT)060-064
SERIAL PORT2E8-2EF8255 PPI (XT)060-063
GPIB (AT)2E0-2E78253 TIMER040-043
EGA2D0-2DF8259 PIC #1020-021
EGA2C0-2CF8237 DMA #1000-00F
FUNCTIONHEX
RANGE
FUNCTIONHEX
RANGE
The CIO-CTRHD BASE switch may be set for address in the range of 000-3F8 so it
should not be hard to find a free address area for your CIO-CTRHD. Once again, if
you are not using IBM prototyping cards or some other board which occupies these