Chapter 34 Data Offsets
25-1
25. DATA OFFSETS
Data Offsets allows the random ordering of Bipolar and Unipolar channel input types to be programmed
into the board channel RAM list.
The Pci55xx Series has 16 channels of analog inputs with programmable gain that’s multiplexed to the 12
or 16-bit A/D converter and supported by 176 elements of channel list RAM. This allows the board to
access individual channels, with different Data Offset settings.
25.1 AL_SetDataOffsetList
Prototype C\C++
ERRNUM AL_SetDataOffsetList(LHLD lhld, LPDATAOFFSETLIST
lpDataOffsetlist);
Visual Basic for Windows
Function AL_SetDataOffsetList(ByVal lhld As Long, lpDataOffsetlist As
DATAOFFSETLIST) As Long
LHLD lhld handle of the LDSD
LPCHANLIST lpchanlist address of the user DATAOFFSET list structure
The AL_SetDataOffsetList function sets the DataOffset list settings in the LDSD. The DataOffset listing
is comprised of a channel number and DataOffset type. The DataOffset list may contain
Channel/DataOffset settings that are not currently set in the channel listing itself, only those channels
selected within the channel list will be set to the appropriate DataOffset type when running. The
DataOffset ID setting in the array can be obtained from the capabilities file.
Parameter Description
lhld Identifies the instance of the logical device subsystem.
lpDataOffsetlist Specifies a 32 bit far pointer to a DATAOFFSET information structure. The
structure has been pre-defined in the ADLIB include file and is defined as
follows:
typedef struct tagDATAOFFSETLIST
{
long lType; /* 0 = Not Defined */
/* 1 = Use string list */
/* 2 = Use array of ints */
char achDataOffsetList[MAX_DATAOFFSET_STRLEN];
long lNumElements;
long alDataOffsetList[MAX_DATAOFFSET_LIST_ARRAYLEN];
}DATAOFFSET;
typedef DATAOFFSET FAR * LPDATAOFFSETLIST;
Returns:
On success ERRNUM is set to 1 and the information contained in the lpDataOffsetlist structure is
transferred to the LDSD, otherwise ERRNUM contains the last error code that occurred during the call.
Zobrazit stránku 110
1 2 ... 106 107 108 109 110 111 112 113 114 115 116 ... 190 191

Komentáře k této Příručce

Žádné komentáře

Microlab SOLO4C manuals

Owner’s manuals and user’s guides for Loudspeakers Microlab SOLO4C.
We providing 1 pdf manuals Microlab SOLO4C for download free by document types: Datasheet






More products and manuals for Loudspeakers Microlab

Models Document Type
Solo 4C User Manual    Microlab Solo 4C, 10 pages
SOLO 15 User Manual    Microlab SOLO 15, 10 pages
B 77 User Manual    Microlab B 77, 10 pages
Solo 6C User Manual    Microlab Solo 6C, 10 pages
Solo2 User Manual   Microlab SOLO2 loudspeaker, 4 pages
M-500II-W User Manual   Microlab M500II-B loudspeaker, 1 pages
M-111 Manual   Microlab M-111 loudspeaker, 1 pages
FC-550 User Manual   Microlab FC-550 loudspeaker, 4 pages
FC-730 User Manual   Microlab FC-730FM loudspeaker, 4 pages
B73 User Manual   Microlab B73 loudspeaker, 1 pages
FC-330 User Manual   Microlab FC-330 loudspeaker, 4 pages
M-1113 User Manual   Microlab M-1113 loudspeaker, 1 pages
SOLO6C User Manual   Microlab SOLO6C loudspeaker, 4 pages
B18 Manual   Microlab B18 loudspeaker, 1 pages
FC-530 User Manual   Microlab FC-530 loudspeaker, 4 pages
IH-11 User Manual   Microlab IH-11 loudspeaker, 4 pages
SOLO3C User Manual   Microlab SOLO3C loudspeaker, 4 pages
SOLO7C User Manual   Microlab SOLO7C loudspeaker, 4 pages
B55 Manual   Microlab B55 loudspeaker, 1 pages
FC550 User Manual     Microlab FC550 User manual, 20 pages