Measurement-computing USB-5106 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Measurement-computing USB-5106. Measurement Computing USB-5106 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - User's Guide

USB-5106 4-channel analog logger User's Guide Document Revision 2 February 2015 © Copyright 2015

Strany 2 - HM USB-5106.docx

USB-5106 User's Guide Functional Details 10 When the plot is configured for events, a New Interval event appears each time the logger enters or

Strany 3 - Table of Contents

USB-5106 User's Guide Functional Details 11 Connecting external sensors The USB-5106 logger can accept up to four external sensors (refer to www

Strany 4 - About this User's Guide

USB-5106 User's Guide Functional Details 12 4-20 mA input cable The 4-20 mA input cable (CABLE-4-20mA) measures current from 0 to 20.1 mA. Do no

Strany 5 - Introducing the USB-5106

USB-5106 User's Guide Functional Details 13 Voltage input adapter cables A voltage input adapter cable is a resistive voltage divider that allow

Strany 6 - Installing the USB-5106

USB-5106 User's Guide Functional Details 14 Mounting the logger There are several ways to mount the USB-5106 using the materials included:  Us

Strany 7 - Functional Details

USB-5106 User's Guide Functional Details 15 Figure 8. Logger rear Caution! Do not cut open, incinerate, heat above 85 °C (185 °F), or recharge

Strany 8 - LCD Screen

16 Chapter 4 Specifications All specifications are subject to change without notice. Typical for 25 °C unless otherwise specified. Specifications in

Strany 9 - Setting up the USB-5106

USB-5106 User's Guide Specifications 17 USB-5106 with cable Table 2. USB-5106 with cable specifications Parameter CABLE-4-20mA CABLE-ADAP5 CABLE

Strany 10 - Alarm modes

Measurement Computing Corporation 10 Commerce Way Suite 1008 Norton, Massachusetts 02766 (508) 946-5100 Fax: (508) 946-9500 E-mail: [email protected]

Strany 11 - Connecting external sensors

HM USB-5106.docx Your new Measurement Computing product comes with a fantastic extra — Management committed to your satisfaction! Thank you for ch

Strany 12

3 Table of Contents Preface About this User's Guide ...

Strany 13 - Reading out the logger

4 Preface About this User's Guide What you will learn from this user's guide This user's guide describes the Measurement Computing USB

Strany 14 - Battery information

5 Chapter 1 Introducing the USB-5106 The USB-5106 is a 4-channel 16-bit analog data logger that can record up to 1.9 million measurements or events.

Strany 15 - Figure 8. Logger rear

6 Chapter 2 Installing the USB-5106 Unpacking As with any electronic device, you should take care while handling to avoid damage from static electric

Strany 16 - Specifications

7 Chapter 3 Functional Details External components The external components on the USB-5106 are shown in Figure 1. 1 Start/Stop button 5 Mounting loo

Strany 17 - USB-5106 with cable

USB-5106 User's Guide Functional Details 8 External sensor inputs Use these 2.5 mm jacks to connect up to four sensors; see Connecting external

Strany 18

USB-5106 User's Guide Functional Details 9 Symbol Description These symbols show the maximum, minimum, average, and standard deviation value

Příbuzné modely USB-5104

Komentáře k této Příručce

Žádné komentáře