Section 3 Command Descriptions
3.22
Status Un
The Status command selects the type of status message the Serial488/4 will
send when addressed to talk on the command address. The
U0
selection causes the
command status to be selected. The
U1
thru
U4
selections cause a serial port status to
be selected. The status of the Serial488/4 may be read at any time without interfering
with normal operation. Any error conditions are cleared after the command status
string is read by the controller. The factory default setting as set by the Save
Configuration command (
S0
) is
U0
, command status is selected.
NOTE: The Status selected is independent of the serial port selected via the Port
command (
Pn
).
U0
Send the Serial488/4 command status when addressed to talk
U1
Send the status of serial port 1 when next addressed to talk
U2
Send the status of serial port 2 when next addressed to talk
U3
Send the status of serial port 3 when next addressed to talk
U4
Send the status of serial port 4 when next addressed to talk
U?
Return the current status command selection
The format of the status byte returned by the Serial488/4 after receiving a
U0
command is as follows:
*.*E#K#M###P#U#Y#Z#####
where each
#
equals the number corresponding to that command. The leading
information
*.*
is the revision level of the Serial488/4 firmware.
Example 1: Read Serial488/4 command status using dual primary addressing mode.
DIM A$(50)
dimension A$
PRINT#1,"CLEAR08"
reset the Serial488/4
PRINT#1,"OUTPUT08;U0X"
send U0 to the Serial488/4
PRINT#1,"ENTER08"
INPUT#2,A$ read the status byte
PRINT A$
shows
1.0E0K1M000P1Y2