Measurement-computing PC104-DAS08 Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Hardware Measurement-computing PC104-DAS08. Measurement Computing PC104-DAS08 User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - User’s Manual

PC104-DAS08User’s ManualRevision 4September, 2001

Strany 2

2 SIGNAL CONNECTIONS 2.1 CONNECTOR DIAGRAMSThe PC104-DAS08 analog connector is a 40-pin header connector.The connector accepts female 40-pinheader

Strany 3 - Table of Contents

Figure 2-3. BP40-37 Adapter Cabling 2.2 ANALOG INPUTSAnalog inputs to the PC104-DAS08 are single-ended.CAUTION - PLEASE READMeasure the voltage betwe

Strany 4

3 REGISTER ARCHITECTURE 3.1 CONTROL & DATA REGISTERSThe PC104-DAS08 is controlled and monitored by writing to and reading from eightconsecutiv

Strany 5 - 1.2 HARDWARE INSTALLATION

Table 3-2. Board RegistersCounter ControlNot usedBASE + 7Load Counter 2Read Counter 2BASE + 6Load Counter 1Read Counter 1BASE + 5Load Counter 0Read Co

Strany 6 - 1 234 56 7

READOn read the most significant A/D byte is read.The A/D Bits code corresponds to the voltage on the input according to Table 4-3.Table 3-3. A/D Bit

Strany 7 - 1.2 .2 INTERRUPT LEVEL SELECT

INTE = 1 enables interrupts (positive edge triggered) onto the PC bus IRQ selectedvia the IRQ jumper on the PC104-DAS08.INTE = 0 disables the passing

Strany 8

The data in the counter read register, and the action taken on the data in a counterload register, is dependent upon the control code written to the c

Strany 9 - 1.2 .3 RANGE SWITCH SETTING

3.7 COUNTER TIMERThe 82C54 counter timer chip can be used for event counting, frequency and pulsemeasurement and as a pacer clock for the A/D converte

Strany 10

counter 1 would then be wired to the interrupt input (pin 10). The slowest ratewould then be once every 17 minutes.3.8 DIGITAL INPUTThe digital input

Strany 11 - Back Plate

4 SPECIFICATIONS Power Consumption+5V: 130 mA typical, 185 mA max+12V: 18 mA typical, 25 mA max−12V: 12 mA typical, 18 mA maxAnalog Input Section

Strany 12 - 3 REGISTER ARCHITECTURE

Your new Measurement Computing product comes with a fantastic extra — Management committed to your satisfaction! Thank you for choosing a Measurement

Strany 13 - 3.2 A/D DATA REGISTER

Digital Input / OutputDigital Type (Main connector)Output: 74LS273Input: 74LS244Configuration 4 fixed output bits, 3 fixed input bitsNumber of ch

Strany 14

For Your Notes17

Strany 16 - 3.6 COUNTER CONTROL REGISTER

EC Declaration of ConformityWe, Measurement Computing Corporation, declare under sole responsibility that theproduct:DescriptionPart NumberAnalog Inpu

Strany 17

Measurement Computing Corporation 10 Commerce Way Suite 1008 Norton, Massachusetts 02766 (508) 946-5100 Fax: (508) 946-9500 E-mail: [email protected]

Strany 18 - 3.9 DIGITAL OUTPUT

154 SPECIFICATIONS ...14 3.10 TRIGGER & INTERRUPT LOGIC...14 3.9 DIGITAL OUTPUT...

Strany 19 - 4 SPECIFICATIONS

This page intentionally left blank.

Strany 20

1 INSTALLATION 1.1 SOFTWARE INSTALLATIONBefore you open your computer and install the board, install and run InstaCal, theinstallation, calibratio

Strany 21 - For Your Notes

1.2 .1 Setting the Base Address SwitchesSelect a base address from those available in your system. The PC104-DAS08 useseight addresses.Set the switch

Strany 22

Table 1-1. PC I/O AddressesSERIAL PORT3F8-3FFEGA2B0-2BFFLOPPY DISK3F0-3F7PARALLEL PRINTER270-27FSERIAL PORT3E8-3EFALT BUS MOUSE23C-23FCGA3D0-3DFBUS MO

Strany 23

Figure 1-3. Interrupt Jumper BlockTable 1-2. IRQ AssignmentsNote: IRQ8-15 are AT onlyLPTIRQ7UNASSIGNEDIRQ15FLOPPY DISKIRQ6HARD DISKIRQ14HARD DISK (

Strany 24

1.2 .3 RANGE SWITCH SETTINGThe DIP switch labeled S2 controls the range (gain) settings for both bipolar ranges(±5V and ±10V), and for the unipolar r

Komentáře k této Příručce