Measurement-computing Micro488/p Uživatelský manuál Strana 28

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 44
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 27
3-10
09-27-02
Command Descriptions
C DEVICE CLEAR
The DEVICE CLEAR command causes the Device Clear (DCL) bus command to be issued
by the Micro488/p. If the optional addresses are included, the Selected Device Clear (SDC)
command is issued to the specified devices. IEEE 488 bus devices which receive a Device
Clear or Selected Device Clear command normally reset to their power-on state.
SYNTAX C[;addr]
RESPONSE None
BUS STATES ATN, DCL (all devices)
ATN, UNL,UNT,LAG,SDC (selected devices)
EXAMPLES PRINT #1,"C" Issue a Device Clear to all devices.
PRINT #1,"C;10" Issue a Selected Device Clear to
device 10.
EC ECHO
The system command ECHO instructs the Micro488/p to either enable, or disable serial
echo.
SYNTAX EC;n
n = 1, enable serial echo.
n = 0, disable serial echo.
RESPONSE None
BUS STATES None
EXAMPLE PRINT#1,"EC;1" Enable serial echo.
Zobrazit stránku 27
1 2 ... 23 24 25 26 27 28 29 30 31 32 33 ... 43 44

Komentáře k této Příručce