CB-7080 & CB-7080D Counter/Timer User's Guide $AA3N(data)
2-19
$AA3N(data)
Description: Set the maximum counter value.
Syntax: $AA3N(data)[chk](cr)
$ A delimiter character
AA 2-character HEX module address, from 00 to FF
N=0 channel-0 of counter or frequency
N=1 channel-1 of counter or frequency
(data) 8-character HEX value.
[chk] 2-character checksum. If checksum is disabled, no [chk]
(cr) 0x0D
Response:
Valid response !AA(data)[chk](cr)
Invalid response ?AA[chk](cr)
no response syntax error, communication error or address error
! A delimiter character indicating a valid response
? A delimiter character indicating an invalid response
AA 2-character HEX module address
[chk] 2-character checksum. If checksum is disabled, no [chk]
(cr) 0x0D
Examples:
Counter-0 from preset value to FFFFh:
command: $01300000FFFF(cr)
response: !01(cr)
Counter-1 from preset value to FFFFFFFFh:
command: $0131FFFFFFFF(cr)
response: !01(cr)