Chapter 2 Utility Analog Input VIs
ADAC LabVIEW VI 32
Utility Analog Input VIs
This section describes the Utility Analog Input VIs that are used to perform analog input
functions. Utility Analog Input VIs provide support for the Easy and Intermediate
Analog Input VIs. Utility Analog Input VIs may also be used as sub VIs in a user
application.
To access the ADAC Analog Input Easy VIs, choose Functions
>>
User Libraries
>>
ADAC
>>
Analog Input
>>
AI Util. The Utility Analog Input VIs are listed in a pop-up
window as follows:
ADAC AI Read One Scan
ADAC AI Wave Scan
ADAC AI Cont Scan
ADAC AI Set Trigger Config
ADAC AI Read One Scan
The ADAC AI Read One Scan VI performs an immediate, untimed acquisition on the
specified channel(s) and returns all the data acquired in scaled data units (volts). This VI
typically acquires voltage readings on a single channel only, but may be used to collect
multiple channels into its 1 dimensional array.