Module Configuration
Up to sixteen DBK84 modules can be attached to a single LogBook or Daq device. Since multiple
modules are connected via a parallel interface, each must have a unique channel address.
CAUTION
Adjustment of the channel address must only be performed when the system
power is OFF. Failure to do so may result in equipment damage.
To assign a channel address to the DBK84 module, first locate the DIP switch on the front panel (next to
P1). Four micro-switches [on the DIP switch] are used to set the module’s channel address in binary.
After ensuring that the system power is OFF, adjust the micro-switches to set the desired address.
Each module in the system must have a unique address.
DBK84 Channel Address Settings
pg. 4, DBK84 989494 DBK Option Cards and Modules